Valid acc. to Price List 05/2008
|
COMMUNICATION DRIVES INCLUDED IN THE PRICE |
||
|
Protocol |
Driver |
Use |
|
COMMUNICATION STANDARDS |
||
|
BAZA |
BAZA |
Communication protocol allows to import data into asix system from databases. Access to database is realized based on ADO technology |
|
BUFOR |
BUFOR |
Communication protocol using memory buffer, data exchange with driver developed by user |
|
CANBUS |
CAN_OPEN |
CANBUS network protocol based on PCI_712 NT card by SELECTRON LYSS AG |
|
CANBUS |
CAN_AC_PCI |
CAN network protocol based on CAN_AC1_PCI and CAN_AC2_PCI cards by Softing GmbH |
|
CANBUS |
GFCAN |
CANBUS network protocol based on CanCard by Garz&Fricke Industrieautomation GmbH |
|
COMLI |
COMLI |
COMmunication LInk protocol allowing communication with AC800C, AC800M and AC250 PLCs from ABB as well as SattCon PLC. Data exchange takes place over RS-232 or RS-485 serial link. |
|
DDE KLIENT |
DDE |
DDE protocol of WINDOWS system, communication with any PLC using its DDE server |
|
FILE2ASIX |
FILE2ASIX |
Communication protocol used for importing data into asix system from the text files of the specified structure |
|
M-BUS |
MBUS |
Serial bus protocol according to EN 1434-3, frequently implemented within heat meters (eq. MULTICAL by KAMSTRUP). Data exchange over RS-232 serial links, (attention: third-party master station of M-Bus network required) |
|
MODBUS RTU |
MODBUS |
Serial bus protocol for MODBUS/RTU, asix as a MASTER |
|
MODBUS SLAVE |
MODBUSSLV |
MODBUS protocol, asix in SLAVE mode |
|
MODBUS TCP |
MODBUS_TCP/IP |
MODBUS network protocol based on TCP/IP, according to OPEN MODBUS/TCP specification by Schneider Electric |
|
OPC KLIENT |
OPC |
OPC (OLE for Process Control) protocol, communication with any PLC using its OPC server, according to OPC 2.04 specification |
|
PROFIBUS DP |
DP |
PROFIBUS DP network protocol, based on PROFIboard card by Softing GmbH |
|
PROFIBUS DP |
DP5412 |
PROFIBUS DP network protocol, based on CP5412 (A2) or CP5613 by Siemens |
|
SIMATIC S5 (Siemens) |
||
|
AS511 |
AS511 |
Protocol using programming device interface of SIMATIC S5 PLC |
|
AS512 |
AS512 |
Protocol of CP524/525/544 communication processors |
|
SINEC L2 |
SINECL2 |
Protocol of PROFIBUS network with SEND/RECEIVE (FDL) interface for SIMATIC S5 |
|
SINEC H1 |
SINECH1 |
Protocol of Ethernet industry network for SIMATIC S5 PLC's, SEND/RECEIVE interface, based on CP1413 |
|
SIMATIC S7 (Siemens) |
||
|
AS512 |
AS512S7 |
AS512 protocol for SIMATIC S7 PLC's, based on CP300 processor |
|
Ethernet |
SAPIS7 |
S7 protocol for Ethernet network |
|
MPI (converter) |
MPI |
Protocol of MPI network for SIMATIC S7 PLC's, based on PC/MPI converter |
|
MPI (CP5611/SOFTNET) |
SAPIS7 |
Protocol of MPI network for SIMATIC S7 PLC's , based on CP5611/SOFTNET |
|
PPI |
PPI |
Protocol of PPI interface for SIMATIC S7 series 200 PLC's, based on PC/PPI converter |
|
PROFIBUS / MPI |
NetLink |
S7 protocol of PROFIBUS network using NetLink Lite module of SYSTEME HELMHOLZ |
| PROFIBUS / MPI | NetLinkPro NEW |
Protocol for exchanging data with S7 PLCs with use of NETLink PRO (gateway Ethernet <-> MPI/Profibus) manufactured by SYSTEME HELMHOLZ |
|
PROFIBUS |
SAPIS7 |
S7 protocol of PROFIBUS network, based on CP5412 (A2) or CP5613 |
|
S7_Ethernet |
S7_TCPIP NEW |
Used for data exchange with SIMATIC S7 PLC’s through Ethernet connection with use of standard computer network card; the product does not require the installation of SIEMENS SIMATIC NET software on asix system PC as well as the adaptation of PLC software for data exchange purposes |
|
BECKHOFF |
||
|
Ethernet |
CtTwinCAT |
Data exchange between ASIX and PLC’s of Beckhoff Industrie Elektronik: BC series, CX1000 and TwinCAT PLC (PC based control system). Communication is based on Ethernet network using ADS interface |
|
GE FANUC (General Electric) |
||
|
SNPX |
CtSNPX |
Serial communication via SNPX protocol with Series 90 and VersaMax PLCs |
|
SRTP |
SRTP |
SRTP protocol allowing communication over TCP/IP with VersaMax Nano/Micro PLC’s ( based on IC200SET001 converter ) and VersaMax or Series 90 PLC's over TCP/IP ( based on IC 693 CMM321) |
|
LG controllers |
||
|
LG proprietary protocol |
CtLG |
Serial communication via dedicated protocol with Master-K and Glofa GM PLCs |
|
MITSUBISHI |
||
|
A1SJ71C24-R2 |
MELSECA |
Serial bus protocol for MELSEC-A and FX2n PLC's, format 1 dedicated |
|
MODICON (AEG, Schneider Electric) |
||
|
MODBUS PLUS |
AM_SA85 |
MODBUS PLUS network protocol, based on Schneider Electric AM-SA85-000 card |
|
SYSMAC (Omron) |
||
|
HOSTLINK |
OMRON |
Serial bus protocol for SYSMAC series PLC's |
|
FESTO |
||
|
FESTO Command Interpreter |
FESTO |
Serial bus protocol for FESTO PLC's , using diagnostic interface |
|
ADAM (Advantech) |
||
|
ADAM 4000 |
ADAM |
RS485 serial bus protocol for ADAM 4000 series modules |
|
SAIA |
||
|
Ethernet S-Bus |
CtSbusTcpip |
Protocol used for data exchange between asix system and PLCs of PCD SAIA-Burgess family by means of TCP/IP |
|
S-Bus |
S-BUS |
Protocol of programmer unit interface and S-Bus network for SAIA Burgess Electronics PLC's |
|
DIGITAL PROTECTION DEVICES |
||
|
AREVA |
AREVA NEW |
Protocol for digital protection devices MiCOM of AREVA; the list of serviced devices includes MiCOM P127 and MiCOM P34x series |
|
CZAZ |
CZAZ NEW |
Protocol for digital protection devices CZAZ-U and CZAZ-UM of ZEG-Energetyka |
|
MUPASZ |
MUPASZ |
Serial bus protocol for universal microprocessor MUPASZ PLC for power industry protection devices - Institute of Telecommunication and Radio Engineering in Warsaw |
|
MUZ |
MUZ |
Protocol of MUZ microprocessor PLC for power industry protection devices |
|
SPA |
SPA |
SPA bus protocol for protection of switching stations manufactured by ABB |
|
SOCOMEC |
MODBUS NEW |
Modbus RTU protocol for communication with devices for measurement and registration of electrical values in 1-, 2- amd 3-phase nets of low and high voltage - DIRIS A10, A20, A40/A41 of SOCOMEC |
|
METERS, REGULATORS AND OTHERS |
||
|
AK |
CtAK |
Protocol for data exchange between asix system and Emerson MLT2 analyzers |
|
AK |
S700 |
Protocol for gas analyzers by MAIHAK |
|
BASKI |
CtBaski |
Protocol for data exchange between asix system and BASKI system |
|
CALEC MCP |
CtCalec |
Communication with CALEC MCP devices by Aquametro |
|
COMPOWAY/F |
K3N |
Universal OMRON meters protocol |
|
DataPAF |
DataPAF |
Communication protocol for energy meters DataPAF |
|
DMS500 |
DMS500 |
Serial bus protocol for DURAG D-MS 500 pollution emission analyzers |
|
DMS285 |
DMS285 |
Serial bus protocol for DURAG D-MS 285 pollution emission analyzers |
|
DSC |
DSC |
DSC PLC protocol (analyzers for chlorine ion content in water) |
|
DXF351 |
DXF351 |
Communication protocol for Compart DXF351 devices by Endress+Hauser |
|
EcoMUZ |
CtEcoMUZ |
Protocol for data exchange between asix and Microprocessor Protecting ecoMUZ Devices made by JM Tronik |
|
FP1001 |
FP1001 |
Serial bus protocol for heat and steam flow meters by METRONIC Kraków |
|
GAZ_MODEM |
MACMAT |
Serial bus protocol for gas flow correctors MACMAT and COMMON |
|
IEC 61107 |
CtZxD400 |
CtZxD400 driver is used for data exchange between asix and electric energy counters of ZxD400 type, manufactured by Landys & Gyr, via RS-485 interface; |
|
K-BUS |
K-BUS |
Communication protocol implemented within DECAMATIC regulators of VIESSMAN boilers |
|
Logo |
CtLogo NEW |
Used to exchange data between asix system and Logo OBA5 controller from SIEMENS with use of programmer interface of the controller |
|
LUMBUS |
LUMBUS |
Communication protocol for meters manufactured by LUMEL |
|
M200 |
CtM200 |
Communication protocol for data exchange between asix and M210G Spirax Sarco stations |
|
MEC |
MEC |
Proprietary protocol allowing communication with heat meters MEC07 and MEC08 manufactured by ITC Łódź. |
|
MEVAS |
MEVAS |
Serial bus protocol for MEVAS pollution emission analyzers |
|
MicroSmart |
MicroSmart NEW |
Used for exchanging data with MicroSmart controllers of IDEC |
|
MN_Invensys |
CtNCP NEW |
Used to exchange data between asix system and MN-series controllers from Invensys (former Satchwell) |
|
MPS |
MPS |
Serial bus protocol for MPS power network parameter meters MPS by OBR Metrologii Elektrycznej in Zielona Góra |
|
MSP1X |
MSP1X |
Serial bus protocol for MSP-1x PLC's by ELMONTEX |
|
MUS |
CtMus04 NEW |
Used to exchange data between asix system and microprocessor-based control devices MUS-04 manufactured by ELEKTROMETAL S.A. from Cieszyn |
|
Pa5 |
CtPa5 |
Communication protocol for data exchange between asix and PA-5 converters of POWOGAZ S.A. Poznan |
|
PMC-4000 |
CtPmc4000 |
Communication protocol for data exchange between asix and POLON 4800 fire alarm control panel; data are transferred via serial interface RS-232 |
|
PROTHERM |
CtProtherm |
Serial bus protocol for Protherm 300 DIFF controller by Process-Electronic GmbH |
|
PROTRONICPS |
PROTRONICPS |
Communication protocol for PROTRONIC PS regulators by Hartmann & Braun |
|
SINTONY SI |
CtSi400 |
Communication protocol for alarm exchanges with Sintony SI 400 of SIEMENS |
|
TALAS |
TALAS |
Serial bus protocol for TALAS pollution emission analyzers according to the TALAS 2.3 (007)22 specification |